TY - JOUR
T1 - A rapid MMP-8 bedside test for the detection of intra-amniotic inflammation identifies patients at risk for imminent preterm delivery
AU - Nien, Jyh Kae
AU - Yoon, Bo Hyun
AU - Espinoza, Jimmy
AU - Kusanovic, Juan Pedro
AU - Erez, Offer
AU - Soto, Eleazar
AU - Richani, Karina
AU - Gomez, Ricardo
AU - Hassan, Sonia
AU - Mazor, Moshe
AU - Edwin, Sam
AU - Bahado-Singh, Ray
AU - Romero, Roberto
N1 - Funding Information:
Supported in part by the Intramural Research Program of the National Institute of Child Health and Human Development, National Institutes of Health, Department of Health and Human Services.
PY - 2006/10/1
Y1 - 2006/10/1
N2 - Objective: Matrix metalloproteinase-8 (MMP-8) is an enzyme that is released during neutrophil activation. MMP-8 amniotic fluid concentrations are elevated not only in patients with intra-amniotic infection, but also in patients with negative amniotic fluid cultures who deliver preterm neonates. The objective of this study was to determine whether the results of a rapid MMP-8 bedside test predict imminent preterm delivery. This test can be performed in 15 minutes and without laboratory equipment. Study design: Amniotic fluid was retrieved from 331 patients admitted with increased preterm uterine contractions and intact membranes who met the inclusion criteria. Amniotic fluid was processed for microbial cultures, Gram stain, glucose concentration, and white blood cell count. Amniotic fluid samples were stored, and the MMP-8 rapid test was performed after delivery. End points included spontaneous preterm delivery within 48 hours, 7 days, and 14 days. Diagnostic indices, predictive values, and likelihood ratios were calculated. Results: The prevalence of spontaneous preterm delivery within 48 hours, 7 days, and 14 days was 11.6% (38/327), 20.2% (66/327), and 24.5% (80/327), respectively (4 patients with augmentation of labor were excluded). A positive MMP-8 rapid test had a positive predictive value of 70% (23/33) for the identification of patients who delivered spontaneously within 48 hours, and 94% (31/33) for patients who were delivered within 7 days and 14 days (likelihood ratios: 17.5 [95% CI, 9-33.9], 61.3 [95% CI, 15.1-250], and 50 [95% CI, 12-196], respectively). Conclusion: The MMP-8 rapid test can identify patients at risk for preterm delivery within 7 days and 14 days. Moreover, a positive MMP-8 rapid test result can identify patients with intra-amniotic infection/inflammation with a high sensitivity and specificity. This rapid test will give clinicians a fast and accurate assessment of the inflammatory status of the amniotic cavity and allow for better identification of patients at risk for impending preterm delivery.
AB - Objective: Matrix metalloproteinase-8 (MMP-8) is an enzyme that is released during neutrophil activation. MMP-8 amniotic fluid concentrations are elevated not only in patients with intra-amniotic infection, but also in patients with negative amniotic fluid cultures who deliver preterm neonates. The objective of this study was to determine whether the results of a rapid MMP-8 bedside test predict imminent preterm delivery. This test can be performed in 15 minutes and without laboratory equipment. Study design: Amniotic fluid was retrieved from 331 patients admitted with increased preterm uterine contractions and intact membranes who met the inclusion criteria. Amniotic fluid was processed for microbial cultures, Gram stain, glucose concentration, and white blood cell count. Amniotic fluid samples were stored, and the MMP-8 rapid test was performed after delivery. End points included spontaneous preterm delivery within 48 hours, 7 days, and 14 days. Diagnostic indices, predictive values, and likelihood ratios were calculated. Results: The prevalence of spontaneous preterm delivery within 48 hours, 7 days, and 14 days was 11.6% (38/327), 20.2% (66/327), and 24.5% (80/327), respectively (4 patients with augmentation of labor were excluded). A positive MMP-8 rapid test had a positive predictive value of 70% (23/33) for the identification of patients who delivered spontaneously within 48 hours, and 94% (31/33) for patients who were delivered within 7 days and 14 days (likelihood ratios: 17.5 [95% CI, 9-33.9], 61.3 [95% CI, 15.1-250], and 50 [95% CI, 12-196], respectively). Conclusion: The MMP-8 rapid test can identify patients at risk for preterm delivery within 7 days and 14 days. Moreover, a positive MMP-8 rapid test result can identify patients with intra-amniotic infection/inflammation with a high sensitivity and specificity. This rapid test will give clinicians a fast and accurate assessment of the inflammatory status of the amniotic cavity and allow for better identification of patients at risk for impending preterm delivery.
KW - Chorioamnionitis
KW - Intact membranes
KW - Intra-amniotic infection/inflammation
KW - MMP-8
KW - Matrix metalloproteinase
KW - Point-of-care test
KW - Prematurity
KW - Preterm labor
UR - http://www.scopus.com/inward/record.url?scp=33748783381&partnerID=8YFLogxK
U2 - 10.1016/j.ajog.2006.06.054
DO - 10.1016/j.ajog.2006.06.054
M3 - Article
AN - SCOPUS:33748783381
SN - 0002-9378
VL - 195
SP - 1025
EP - 1030
JO - American Journal of Obstetrics and Gynecology
JF - American Journal of Obstetrics and Gynecology
IS - 4
ER -