Abstract
AC losses in hollow BSCCO cylinders used in an inductive fault current limiter model have been investigated theoretically and experimentally. Discrepancies, becoming more pronounced with increasing current, between the experimental results and predictions of Bean's critical state model were observed. A simple procedure of calculating AC losses by taking into account the real form of the E-J characteristics was proposed. AC loss characteristics were employed to evaluate the nominal and activation currents of the full-scale fault current limiter.
| Original language | English |
|---|---|
| Pages (from-to) | 1361-1364 |
| Number of pages | 4 |
| Journal | IEEE Transactions on Applied Superconductivity |
| Volume | 9 |
| Issue number | 2 PART 1 |
| DOIs | |
| State | Published - 1 Dec 1999 |
ASJC Scopus subject areas
- Electronic, Optical and Magnetic Materials
- Condensed Matter Physics
- Electrical and Electronic Engineering
Fingerprint
Dive into the research topics of 'AC losses in BSCCO cylinders operating in inductive current limiter'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver