Skip to main navigation Skip to search Skip to main content

Artificial Intelligence-Derived Fractional Flow Reserve in Routine Clinical Practice: An International Multicenter Retrospective Study

  • Eyal Ben-Assa
  • , Bruce A. Samuels
  • , Ehtisham Mahmud
  • , Carlos Cafri
  • , Ariel Roguin
  • , Yair Feld
  • , Eli Lev
  • , Emanuel Harari
  • , Tali Ben-Yehuda
  • , Hector M. Garcia-Garcia
  • , Gregg W. Stone

Research output: Contribution to journal › Article › peer-review

2 Scopus citations

Abstract

Background Artificial intelligence-based fractional flow reserve (AI-FFR) incorporates a machine learning-based algorithm to derive FFR directly from angiography. Its accuracy compared with invasive FFR has not been assessed. Methods AI-FFR was compared with wire-based FFR in patients with a single intermediate lesion (diameter stenosis ≥40% to <70%) at 5 centers in the United States and Israel. AI-FFR assessments were performed by core laboratory analysts blinded to invasive FFR results. Diagnostic performance metrics were calculated using an FFR threshold of ≤0.80. Results A total of 504 vessels from 496 patients were analyzed. AI-FFR computation time was 36.1 ± 7.7 seconds. Lesion detection was fully automatic in 371 of 504 (73.6%) vessels, whereas semiautomated analysis with manual marking was performed in 133 of 504 (26.4%) vessels. Mean wire-based FFR was 0.85 ± 0.07 and mean AI-FFR was 0.85 ± 0.08 (mean difference, 0.00 ± 0.08; 95% CI, −0.15 to 0.15; P = .41). AI-FFR showed a sensitivity of 90.2%, specificity of 94.9%, positive predictive value of 83.5%, negative predictive value of 97.1%, and overall diagnostic accuracy of 93.8%. The area under the receiver operating characteristic curve (AUC) was 0.93 (95% CI, 0.89-0.96). Among 151 lesions with wire-based FFR values in the borderline “gray zone” (0.75-0.85), AI-FFR demonstrated a diagnostic accuracy of 91.4% and an AUC of 0.91 (95% CI, 0.86-0.96). AI-FFR demonstrated high diagnostic accuracy across vessel types and lesion locations in men and women and between the US and Israeli cohorts. Conclusions AI-FFR, an automated, machine learning-based tool, demonstrated high diagnostic accuracy compared with wire-based FFR. Its speed, simplicity, and independence from complex procedural steps may facilitate broader adoption during coronary angiography.

Original languageEnglish
Article number105451
JournalJournal of the Society for Cardiovascular Angiography and Interventions
Volume5
Issue number8
DOIs
StatePublished - 1 Aug 2026

Keywords

  • angiography
  • artificial intelligence
  • artificial intelligence-derived fractional flow reserve
  • fractional flow reserve

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'Artificial Intelligence-Derived Fractional Flow Reserve in Routine Clinical Practice: An International Multicenter Retrospective Study'. Together they form a unique fingerprint.

Cite this