Skip to main navigation Skip to search Skip to main content

Artificial intelligence–augmented electrocardiography for left ventricular systolic dysfunction in patients undergoing high-sensitivity cardiac troponin T

  • Laura De Michieli
  • , Jonathan D. Knott
  • , Zachi I. Attia
  • , Olatunde Ola
  • , Ramila A. Mehta
  • , Ashok Akula
  • , David O. Hodge
  • , Rajiv Gulati
  • , Paul A. Friedman
  • , Allan S. Jaffe
  • , Yader Sandoval

Research output: Contribution to journalArticlepeer-review

9 Scopus citations

Abstract

Aims Our goal was to evaluate a previously validated artificial intelligence–augmented electrocardiography (AI-ECG) screening tool for left ventricular systolic dysfunction (LVSD) in patients undergoing high-sensitivity-cardiac troponin T (hs-cTnT). Methods and results Retrospective application of AI-ECG for LVSD in emergency department (ED) patients undergoing hs-cTnT. AI-ECG scores (0–1) for probability of LVSD (left ventricular ejection fraction ≤ 35%) were obtained. An AI-ECG score ≥0.256 indicates a positive screen. The primary endpoint was a composite of post-discharge major adverse cardiovascular events (MACEs) at two years follow-up. Among 1977 patients, 248 (13%) had a positive AI-ECG. When compared with patients with a negative AI-ECG, those with a positive AI-ECG had a higher risk for MACE [48 vs. 21%, P < 0.0001, adjusted hazard ratio (HR) 1.39, 95% confidence interval (CI) 1.11–1.75]. This was largely because of a higher rate of deaths (32 vs. 14%, P < 0.0001; adjusted HR 1.26, 95% 0.95–1.66) and heart failure hospitalizations (26 vs. 6.1%, P < 0.001; adjusted HR 1.75, 95% CI 1.25–2.45). Together, hs-cTnT and AI-ECG resulted in the following MACE rates and adjusted HRs: hs-cTnT < 99th percentile and negative AI-ECG: 116/1176 (11%; reference), hs-cTnT < 99th percentile and positive AI-ECG: 28/107 (26%; adjusted HR 1.54, 95% CI 1.01–2.36), hs-cTnT > 99th percentile and negative AI-ECG: 233/553 (42%; adjusted HR 2.12, 95% CI 1.66, 2.70), and hs-cTnT > 99th percentile and positive AI-ECG: 91/141 (65%; adjusted HR 2.83, 95% CI 2.06, 3.87). Conclusion Among ED patients evaluated with hs-cTnT, a positive AI-ECG for LVSD identifies patients at high risk for MACE. The conjoint use of hs-cTnT and AI-ECG facilitates risk stratification.

Original languageEnglish
Pages (from-to)106-114
Number of pages9
JournalEuropean Heart Journal: Acute Cardiovascular Care
Volume12
Issue number2
DOIs
StatePublished - 1 Feb 2023
Externally publishedYes

Keywords

  • Artificial intelligence
  • Electrocardiogram
  • High-sensitivity-cardiac troponin
  • Myocardial infarction
  • Myocardial injury

ASJC Scopus subject areas

  • Critical Care and Intensive Care Medicine
  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'Artificial intelligence–augmented electrocardiography for left ventricular systolic dysfunction in patients undergoing high-sensitivity cardiac troponin T'. Together they form a unique fingerprint.

Cite this