Skip to main navigation Skip to search Skip to main content

Brewer’s Spent Grain-Cellulose-Coated Copper Electrode-Based Extended Gate Field-Effect Transistor for Nonenzymatic Glucose Detection toward Diagnosis of Diabetes Mellitus

  • Akshaya Vinukumar
  • , Mallikarjuna Swamy Shabanur Matada
  • , Guru Prasad Kuppuswamy
  • , Sreeram Jayan
  • , Kripa Vivek
  • , Surya Velappa Jayaraman
  • , Yuvaraj Sivalingam
  • , Noemi Tocci
  • , Abirami Ramu Ganesan
  • , Lorenza Conterno

Research output: Contribution to journal › Article › peer-review

9 Scopus citations

Abstract

The demand for environmentally friendly, reliable, and cost-effective electrodes for glucose sensor technology has become a major research area in the paradigm shift toward green electronics. In this regard, cellulose has emerged as a promising flexible biopolymer solution with unique properties such as biocompatibility, biodegradability, nontoxicity, renewability, and sustainability. Because of their large surface area and porous structure, fibrous cellulose substrates quickly adsorb and disperse analytes at detection sites. This work focuses on utilizing glyoxal-treated cellulose (derived from brewer’s spent grain (BSG)) for the fabrication of extended gate field-effect transistor (EGFET)-based glucose sensors. This investigation extends to the utilization of BSG-cellulose for glucose detection in biomimicking electrolytes (phosphate buffer saline) to facilitate glucose detection in human blood samples. The fabricated electrode demonstrates a linear range of glucose detection from 1 to 13.5 mM with a Langmuir adsorption coefficient (K) of 0.102. Also, its selectivity toward glucose over interfering molecules such as sucrose, fructose, ascorbic acid, and uric acid under physiological conditions has been demonstrated. This cellulose-based EGFET electrode exhibits a sensitivity of 6.5 μA mM−1 cm−2 with a limit of detection (LOD) of 0.135 mM. Computational studies by density functional theory calculations confirmed the higher binding affinity of glucose molecules with glyoxal-modified cellulose (−0.95 eV) than with pristine cellulose (−0.46 eV). Here, the novelty lies in the fabrication of electrodes with biodegradable catalysts and their integration into the EGFET configuration.

Original languageEnglish
Pages (from-to)53405-53418
Number of pages14
JournalACS Applied Materials and Interfaces
Volume16
Issue number40
DOIs
StatePublished - 9 Oct 2024
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • EGFET biosensor
  • brewer’s spent grain cellulose
  • diabetes mellitus
  • glucose
  • glyoxal-modified cellulose
  • scanning kelvin probe

ASJC Scopus subject areas

  • General Materials Science

Fingerprint

Dive into the research topics of 'Brewer’s Spent Grain-Cellulose-Coated Copper Electrode-Based Extended Gate Field-Effect Transistor for Nonenzymatic Glucose Detection toward Diagnosis of Diabetes Mellitus'. Together they form a unique fingerprint.

Cite this