Comparative analysis of some modal reconstruction methods of the shape of the cornea from corneal elevation data

  • Andrei Martinez-Finkelshtein
  • , Antonia M. Delgado
  • , Gracia M. Castro
  • , Alejandro Zarzo
  • , Jorge L. Alio

Research output: Contribution to journalArticlepeer-review

23 Scopus citations

Abstract

Purpose. A comparative study of the ability of some modal schemes to reproduce corneal shapes of varying complexity was performed, by using both standard radial polynomials and radial basis functions (RBFs). The hypothesis was that the correct approach in the case of highly irregular corneas should combine several bases.Methods. Standard approaches of reconstruction by Zernike and other types of radial polynomials were compared with the discrete least-squares fit (LSF) by the RBF in three theoretical surfaces, synthetically generated by computer algorithms in the absence of measurement noise. For the reconstruction by polynomials, the maximal radial order 6 was chosen, which corresponds to the first 28 Zernike polynomials or the first 49 Bhatia-Wolf polynomials. The fit with the RBF was performed by using a regular grid of centers.Results. The quality of fit was assessed by computing for each surface the mean square errors (MSEs) of the reconstruction by LSF, measured at the same nodes where the heights were collected. Another criterion of the fit quality used was the accuracy in recovery of the Zernike coefficients, especially in the case of incomplete data.Conclusions. The Zernike (and especially, the Bhatia-Wolf) polynomials constitute a reliable reconstruction method of a nonseverely aberrated surface with a small surface regularity index (SRI). However, they fail to capture small deformations of the anterior surface of a synthetic cornea. The most promising approach is a combined one that balances the robustness of the Zernike fit with the localization of the RBF.

Original languageEnglish
Pages (from-to)5639-5645
Number of pages7
JournalInvestigative Ophthalmology and Visual Science
Volume50
Issue number12
DOIs
StatePublished - 1 Dec 2009
Externally publishedYes

ASJC Scopus subject areas

  • Ophthalmology
  • Sensory Systems
  • Cellular and Molecular Neuroscience

Fingerprint

Dive into the research topics of 'Comparative analysis of some modal reconstruction methods of the shape of the cornea from corneal elevation data'. Together they form a unique fingerprint.

Cite this