Abstract
Background The majority of transcatheter aortic valve implantation (TAVI) procedures are currently performed by percutaneous transfemoral approach. The potential contribution of the type of vascular closure device to the incidence of vascular complications is not clear. Aim To compare the efficacy of a Prostar XL-vs. Perclose ProGlide-based vascular closure strategy. Methods The ClOsure device iN TRansfemoral aOrtic vaLve implantation (CONTROL) multi-center study included 3138 consecutive percutaneous transfemoral TAVI patients, categorized according to vascular closure strategy: Prostar XL-(Prostar group) vs. Perclose ProGlide-based vascular closure strategy (ProGlide group). Propensity-score matching was used to assemble a cohort of patients with similar baseline characteristics. Results Propensity matching identified 944 well-matched patients (472 patient pairs). Composite primary end point of major vascular complications or in-hospital mortality occurred more frequently in Prostar group when compared with ProGlide group (9.5 vs. 5.1%, P = 0.016), and was driven by higher rates of major vascular complication (7.4 vs. 1.9%, P < 0.001) in the Prostar group. However, in-hospital mortality was similar between groups (4.9 vs. 3.5%, P = 0.2). Femoral artery stenosis occurred less frequently in the Prostar group (3.4 vs. 0.5%, P = 0.004), but overall, Prostar use was associated with higher rates of major bleeding (16.7 vs. 3.2%, P < 0.001), acute kidney injury (17.6 vs. 4.4%, P < 0.001) and with longer hospital stay (median 6 vs. 5 days, P = 0.007). Conclusions Prostar XL-based vascular closure in transfemoral TAVI procedures is associated with higher major vascular complication rates when compared with ProGlide; however, in-hospital mortality is similar with both devices.
| Original language | English |
|---|---|
| Pages (from-to) | 3370-3379 |
| Number of pages | 10 |
| Journal | European Heart Journal |
| Volume | 36 |
| Issue number | 47 |
| DOIs | |
| State | Published - 14 Dec 2015 |
| Externally published | Yes |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 3 Good Health and Well-being
Keywords
- Aortic stenosis
- Transcatheter aortic valve replacement
- Vascular closure device
- Vascular complication
ASJC Scopus subject areas
- Cardiology and Cardiovascular Medicine
Fingerprint
Dive into the research topics of 'Comparison of vascular closure devices for access site closure after transfemoral aortic valve implantation'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver