Cryoballoon-Induced Circumferential Pulmonary Vein Fibrosis, Assessed by Late Gadolinium-Enhancement Cardiac Magnetic Resonance Imaging, and Its Correlation with Clinical Atrial Fibrillation Recurrence

Moshe Rav Acha, Oholi Tovia-Brodie, Yoav Michowitz, Feras Bayya, Fauzi F. Shaheen, Shalom Abuhatzera, Aharon Medina, Michael Glikson, Arik Wolak

Research output: Contribution to journalArticlepeer-review

3 Scopus citations

Abstract

Background: Prior studies evaluating post-atrial fibrillation (AF) ablation pulmonary vein (PV) ostial gaps via magnetic resonance imaging (MRI) have shown circumferential PV fibrosis in a minority of patients, and their correlation with AF recurrence was weak. These studies were mostly based on radio-frequency AF ablations. Aim: We aimed to assess cryoballoon ablation-induced PV fibrosis via MRI and its correlation with AF recurrence. Methods and Results: This was a prospective study of consecutive patients with symptomatic AF who underwent pre- and post-ablation MRI to assess baseline and ablation-induced fibrosis, respectively. Post-ablation PV gaps were assessed by new semi-quantitative visual analysis assisted by computerized ADAS analysis. AF recurrence monitored via multiple ECGs and event monitoring at 6 and 12 months post ablation. Nineteen patients with 80 PVs were included, age 56 ± 11, with paroxysmal and persistent AF in 17/19 and 2/19 patients, respectively. Baseline MRI showed minimal LA fibrosis. All patients underwent successful cryoballoon PV electrical isolation. Post-ablation MRI revealed circumferential PV fibrosis among 63/80 (78.8%) PVs and partial fibrosis with major gaps among 17/80 (21.2%) PVs. AF recurred within one year in 5/9 (55.5%) patients with partial PV fibrosis, while no AF recurred among the 10 patients in whom all PVs had circumferential fibrosis (p < 0.01). Similarly, there were significantly more PVs without circumferential fibrosis (due to major gaps) among patients with AF recurrence as compared with patients without AF recurrence (42.9% vs. 13.5%; p < 0.01). Conclusion: Cryoballoon AF ablation results in circumferential PV fibrosis in the majority of PVs, as assessed by a new clinically relevant MRI-LGE analysis. Significant correlation was found between major PV gaps on post-ablation MRI and AF recurrence, suggesting that MRI might have the ability to predict AF recurrence.

Original languageEnglish
Article number2442
JournalJournal of Clinical Medicine
Volume12
Issue number6
DOIs
StatePublished - 1 Mar 2023
Externally publishedYes

Keywords

  • ablation-induced
  • AF
  • cryoballoon
  • fibrosis
  • MRI
  • recurrence

ASJC Scopus subject areas

  • General Medicine

Fingerprint