Abstract
We propose and analyze the use of fluorescence phase-shifting interferometric (PSI) imaging for single particle tracking along 1 μm-depth (z) trajectories. While spatial PSI using a single camera attains a maximal twofold improvement in the z-localization precision compared to temporal PSI for <0.1 μm2/s diffusion, temporal PSI shows a fourfold larger field-of-view.
Original language | English |
---|---|
Title of host publication | CLEO |
Subtitle of host publication | Science and Innovations, CLEO_SI 2013 |
Pages | CTu3N.4 |
State | Published - 18 Nov 2013 |
Event | CLEO: Science and Innovations, CLEO_SI 2013 - San Jose, CA, United States Duration: 9 Jun 2013 → 14 Jun 2013 |
Publication series
Name | CLEO: Science and Innovations, CLEO_SI 2013 |
---|
Conference
Conference | CLEO: Science and Innovations, CLEO_SI 2013 |
---|---|
Country/Territory | United States |
City | San Jose, CA |
Period | 9/06/13 → 14/06/13 |
ASJC Scopus subject areas
- Computer Networks and Communications
- Electrical and Electronic Engineering
- Electronic, Optical and Magnetic Materials
- Atomic and Molecular Physics, and Optics