Abstract
We have measured the change of fluorescence from cold 87Rb atoms after magnetic field of the magneto-optic trap is turn off. A rise in fluorescence within several tens of milliseconds was observed. Analyzing this phenomenon in connection with the experimental conditions, we found that incoherent pumping field due to radiation trapping in the high density cold-atom cloud was the reason of fluorescence weakening under tight confinement by the magneto-optic trap. We have also performed a simple numerical simulation, which indicated that the calculations agree with experimental results only when the effect of frequency redistribution of scattered light is taken into account.
Original language | English |
---|---|
Pages (from-to) | 1590-1594 |
Number of pages | 5 |
Journal | Wuli Xuebao/Acta Physica Sinica |
Volume | 58 |
Issue number | 3 |
State | Published - 1 Mar 2009 |
Externally published | Yes |
Keywords
- Cold-atom cloud
- Frequency redistribution
- Radiation trapping
ASJC Scopus subject areas
- General Physics and Astronomy