Abstract
A new approach for neutron detection enhancement to scintillator gamma-ray detectors is suggested. By using a scintillator coupled with a boron carbide (B4C) disc, the 478 keV gamma-photon emitted from the excited Li in 94% of the 10B(n,α)7Li interactions was detected. This suggests that the performance of existing gamma detection systems in Homeland security applications can be improved. In this study, a B4C disc (2 in. diameter, 0.125 in. thick) with ∼19.8% 10B was used and coupled with a scintillator gamma-ray detector. In addition, the neutron thermalization moderator was studied in order to be able to increase the neutron sensitivity. An improvement in the detector which is easy to assemble, affordable and efficient was demonstrated. Furthermore, a tailored Monte-Carlo code written in MATLAB was developed for validation of the proposed application through efficiency estimation for thermal neutrons. Validation of the code was accomplished by showing that the MATLAB code results were well correlated to a Monte-Carlo MCNP code results. The measured efficiency of the assembled experimental model was observed to be in agreement with both models calculations.
Original language | English |
---|---|
Pages (from-to) | 62-67 |
Number of pages | 6 |
Journal | Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment |
Volume | 756 |
DOIs | |
State | Published - 21 Aug 2014 |
Keywords
- Boron carbide
- MATLAB
- MCNP
- Monte Carlo
- Neutron detection
- Scintillator
ASJC Scopus subject areas
- Nuclear and High Energy Physics
- Instrumentation