Abstract
The mechanism of duty cycle generation in current mode (CM) and average current mode (ACM) PWM convertors is examined and found to be identical except for the functional relationship of the controlling parameters. This result is used to develop a SPICE compatible and topology independent generic current mode (GCM) model.
Original language | English |
---|---|
Pages (from-to) | 1356-1358 |
Number of pages | 3 |
Journal | Electronics Letters |
Volume | 28 |
Issue number | 14 |
DOIs | |
State | Published - 2 Jul 1992 |
Keywords
- Circuit theory and design
- Convertors
- Modelling
- Switching and switching circuits
ASJC Scopus subject areas
- Electrical and Electronic Engineering