Abstract
We investigated the hydrogen distribution spatially and temporally in technical iron at room temperature. Samples were charged electrochemically and subsequently analysed by means of neutron radiography and tomography. The radiographic images allowed for a time-resolved analysis of hydrogen fluxes. The three-dimensional distribution of hydrogen measured by neutron tomography delivered valuable information for the damage analysis of hydrogen-induced cracks. For the first time hydrogen concentration gradients inside the material could be detect directly together with the cracks. The neutron radiography and tomography results were gained at the Research Reactor BER II of the HZB in Berlin.
| Original language | English |
|---|---|
| Pages (from-to) | 640-644 |
| Number of pages | 5 |
| Journal | International Journal of Materials Research |
| Volume | 105 |
| Issue number | 7 |
| DOIs | |
| State | Published - 1 Jan 2014 |
| Externally published | Yes |
Keywords
- Blister
- Hydrogen diffusion
- Hydrogen embrittlement
- Neutron tomography
ASJC Scopus subject areas
- Condensed Matter Physics
- Physical and Theoretical Chemistry
- Metals and Alloys
- Materials Chemistry