Skip to main navigation Skip to search Skip to main content

In situ Mg/Ca measurements on foraminifera: Comparison between laser ablation inductively coupled plasma mass spectrometry and wavelength-dispersive X-ray spectroscopy by electron probe microanalyzer

  • B. Balestra
  • , T. Rose
  • , J. Fehrenbacher
  • , K. D. Knobelspiesse
  • , B. T. Huber
  • , T. Gooding
  • , A. Paytan

Research output: Contribution to journalArticlepeer-review

7 Scopus citations

Abstract

We present a comparison of two different techniques: Laser Ablation Inductively Coupled Plasma Mass Spectrometry (LA-ICP-MS) and wavelength-dispersive X-Ray Spectroscopy by electron probe microanalyzer (EPMA) for obtaining Mg/Ca ratios in individual foraminifera shells. The goal is to assess the use of EPMA as an alternative technique for Mg/Ca analyses of single foraminiferal calcite shells. Foraminifera obtained from sediments (benthic, Uvigerina spp.) and from plankton tows (planktonic, Orbulina universa) were analyzed. All specimens were prepared in epoxy mounts and exposed in cross-section such that multiple high-resolution analyses could be completed on the shells using both techniques. We examined our data using statistical methods designed for the assessment and comparison of measurement techniques. In the case of Uvigerina, the mean difference for ratios obtained using EPMA and LA-ICP-MS is very small (−0.046 mmol mol−1) and scale independent. The Limits of Agreement (LoA, the standard deviation of the bias plus the mean bias) is [−0.315, 0.223] mmol mol−1. For samples with ratios lower than 13 mmol mol−1, we found a mean EPMA–LA-ICP-MS bias of −2.44 mmol mol−1 and a corresponding LoA of [−3.85, −1.04] mmol mol−1. For ratios higher than 13 mmol mol−1, there appears to be a scale dependent bias, meaning that the EPMA measured ratios become progressively larger than those of LA-ICP-MS as the Mg/Ca ratio increases, so the mean bias and LoA metrics are not meaningful. Results indicate that it is possible to use EPMA to collect Mg/Ca data, if the ratios are lower than ~13 mmol mol−1.

Original languageEnglish
Article numbere2020GC009449
Pages (from-to)1-10
Number of pages10
JournalGeochemistry, Geophysics, Geosystems
Volume22
Issue number2
DOIs
StatePublished - 1 Feb 2021
Externally publishedYes

ASJC Scopus subject areas

  • Geophysics
  • Geochemistry and Petrology

Fingerprint

Dive into the research topics of 'In situ Mg/Ca measurements on foraminifera: Comparison between laser ablation inductively coupled plasma mass spectrometry and wavelength-dispersive X-ray spectroscopy by electron probe microanalyzer'. Together they form a unique fingerprint.

Cite this