Abstract
The general solution of the linear compartmental model for the cerebrovascular fluid system with constant resistances and compliances predicts the pressure waves in the compartments in response to an input pulse wave-arterial and/or jugular. Results are shown for a seven-compartment model and for a sinusoidal arterial pulse wave at a frequency of 1 Hz, with and without fluid drainage from the CSF compartment. z.
| Original language | English |
|---|---|
| Pages (from-to) | 149-159 |
| Number of pages | 11 |
| Journal | Mathematical Biosciences |
| Volume | 89 |
| Issue number | 2 |
| DOIs | |
| State | Published - 1 Jan 1988 |
| Externally published | Yes |
ASJC Scopus subject areas
- Statistics and Probability
- Modeling and Simulation
- General Biochemistry, Genetics and Molecular Biology
- General Immunology and Microbiology
- General Agricultural and Biological Sciences
- Applied Mathematics
Fingerprint
Dive into the research topics of 'Intracranial compartmental pulse-wave simulation'. Together they form a unique fingerprint.Cite this