Skip to main navigation Skip to search Skip to main content

Multi-probe-based resonance-frequency electrical impedance spectroscopy for detection of suspicious breast lesions: Improving performance using partial ROC optimization

  • Dror Lederman
  • , Bin Zheng
  • , Xingwei Wang
  • , Xiao Hui Wang
  • , David Gur

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

Abstract

We have developed a multi-probe resonance-frequency electrical impedance spectroscope (REIS) system to detect breast abnormalities. Based on assessing asymmetry in REIS signals acquired between left and right breasts, we developed several machine learning classifiers to classify younger women (i.e., under 50YO) into two groups of having high and low risk for developing breast cancer. In this study, we investigated a new method to optimize performance based on the area under a selected partial receiver operating characteristic (ROC) curve when optimizing an artificial neural network (ANN), and tested whether it could improve classification performance. From an ongoing prospective study, we selected a dataset of 174 cases for whom we have both REIS signals and diagnostic status verification. The dataset includes 66 "positive" cases recommended for biopsy due to detection of highly suspicious breast lesions and 108 "negative" cases determined by imaging based examinations. A set of REIS-based feature differences, extracted from the two breasts using a mirror-matched approach, was computed and constituted an initial feature pool. Using a leave-one-case-out cross-validation method, we applied a genetic algorithm (GA) to train the ANN with an optimal subset of features. Two optimization criteria were separately used in GA optimization, namely the area under the entire ROC curve (AUC) and the partial area under the ROC curve, up to a predetermined threshold (i.e., 90% specificity). The results showed that although the ANN optimized using the entire AUC yielded higher overall performance (AUC = 0.83 versus 0.76), the ANN optimized using the partial ROC area criterion achieved substantially higher operational performance (i.e., increasing sensitivity level from 28% to 48% at 95% specificity and/ or from 48% to 58% at 90% specificity).

Original languageEnglish
Title of host publicationMedical Imaging 2011
Subtitle of host publicationComputer-Aided Diagnosis
DOIs
StatePublished - 13 May 2011
Externally publishedYes
EventMedical Imaging 2011: Computer-Aided Diagnosis - Lake Buena Vista, FL, United States
Duration: 15 Feb 201117 Feb 2011

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume7963
ISSN (Print)1605-7422

Conference

ConferenceMedical Imaging 2011: Computer-Aided Diagnosis
Country/TerritoryUnited States
CityLake Buena Vista, FL
Period15/02/1117/02/11

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • AUC
  • Electrical impedance spectroscope (EIS)
  • ROC
  • artificial neural network
  • breast cancer
  • partial AUC
  • technology assessment

ASJC Scopus subject areas

  • Electronic, Optical and Magnetic Materials
  • Atomic and Molecular Physics, and Optics
  • Biomaterials
  • Radiology Nuclear Medicine and imaging

Fingerprint

Dive into the research topics of 'Multi-probe-based resonance-frequency electrical impedance spectroscopy for detection of suspicious breast lesions: Improving performance using partial ROC optimization'. Together they form a unique fingerprint.

Cite this