Multivariate analysis of risk factors for re-dislocation after revision for dislocation after total hip arthroplasty

Amir Herman, Bassam A. Masri, Clive P. Duncan, Nelson V. Greidanus, Donald S. Garbuz

Research output: Contribution to journalArticlepeer-review

15 Scopus citations

Abstract

Background: The treatment for recurrent dislocation of a total hip arthroplasty is surgical using varied techniques and technologies to reduce the chances of re-dislocation and re-revision. The goal of this study is to compare operative techniques to reduce re-dislocation and re-revision in revision hip arthroplasty due to recurrent dislocations. Methods: A retrospective study of revision hip arthroplasties done due to recurrent dislocation prior to 01 January 2014. Electronic physician and provincial health records were used to collect patients’ initial and follow-up data. Treatment failure was defined as either aseptic re-revision or re-dislocation without revision. Time to event was considered as the re-revision date or the date of second dislocation when the latter endpoint was used. Results: Of 379 operations, 88 (23.2%) had aseptic repeat revision or recurrent dislocation. Of these: 66 (75.0%) due to dislocation with re-revision; 10 (11.4%) due to dislocation with no re-revision surgery; 5 (5.7%) due to aseptic loosening of components; 3 (3.4%) due to osteolysis; 3 (3.4%) due to pseudotumour; and 1 (1.1%) due to periprosthetic fracture. The following factors increase risk of failure: the use of augmented-liners (lipped, oblique and high-offset liners; HR = 1.68, 95% CI, 1.05–2.69), periprosthetic femur fracture (HR = 2.80, 95% CI, 1.39–8.21) and pelvic discontinuity (HR = 3.69, 95% CI, 1.66–8.21). Femur head sizes 36–40 mm are protective (HR = 0.54, 95% CI, 0.31–0.86). In abductor dysfunction the use of focal constrained liners decreases the risk of failure (HR = 0.13, 95% CI, 0.018–0.973). Conclusions: Larger head sizes and focal constrained liners (abductors dysfunction) should be used and fully constrained liners and augmented-liners should be avoided in a revision hip arthroplasty due to recurrent dislocations.

Original languageEnglish
Pages (from-to)93-100
Number of pages8
JournalHIP International
Volume30
Issue number1
DOIs
StatePublished - 1 Jan 2020

Keywords

  • Abductors deficiency
  • augmented liners
  • hip dislocation
  • hip revision

ASJC Scopus subject areas

  • Surgery
  • Orthopedics and Sports Medicine

Fingerprint

Dive into the research topics of 'Multivariate analysis of risk factors for re-dislocation after revision for dislocation after total hip arthroplasty'. Together they form a unique fingerprint.

Cite this