Skip to main navigation Skip to search Skip to main content

Novel use of neonatal cuffed tracheal tube to occlude tracheo- oesophageal fistula

Research output: Contribution to journalArticlepeer-review

13 Scopus citations

Abstract

The use of a cuffed tracheal tube is described to occlude the leak through a tracheo-oesophageal fistula (TOF) in a neonate and prevent gastric dilatation during positive-pressure lung ventilation.

Original languageEnglish
Pages (from-to)339-341
Number of pages3
JournalPaediatric Anaesthesia
Volume9
Issue number4
DOIs
StatePublished - 13 Jul 1999