Abstract
In this brief, extension of known rules for designing optimized single-resonant ac current regulators to multiresonant current regulators parameter selection for single-phase grid-connected photovoltaic inverters is proposed. The proposed generalization is made possible by utilizing multiplied rather than summed resonant terms within the controller. A set of phase-margin oriented design guidelines is established, explicitly defining each controller parameter to corresponding figure of merit. Simulations and matching experimental results are shown to verify the proposed approach.
Original language | English |
---|---|
Article number | 8844968 |
Pages (from-to) | 1815-1818 |
Number of pages | 4 |
Journal | IEEE Journal of Photovoltaics |
Volume | 9 |
Issue number | 6 |
DOIs | |
State | Published - 1 Nov 2019 |
Keywords
- Current control
- distorted grid
- grid-connected inverters
- multiresonant (MR) control
ASJC Scopus subject areas
- Electronic, Optical and Magnetic Materials
- Condensed Matter Physics
- Electrical and Electronic Engineering