TY - JOUR
T1 - Safety and feasibility of robotic percutaneous coronary intervention
T2 - PRECISE (percutaneous robotically-enhanced coronary intervention) study
AU - Weisz, Giora
AU - Metzger, D. Christopher
AU - Caputo, Ronald P.
AU - Delgado, Juan A.
AU - Marshall, J. Jeffrey
AU - Vetrovec, George W.
AU - Reisman, Mark
AU - Waksman, Ron
AU - Granada, Juan F.
AU - Novack, Victor
AU - Moses, Jeffrey W.
AU - Carrozza, Joseph P.
PY - 2013/4/16
Y1 - 2013/4/16
N2 - Objectives: The aim of this study was to evaluate the safety as well as the clinical and technical effectiveness of robotic-assisted percutaneous coronary intervention. Background: Robotic systems have been suggested to enhance the performance of cardiovascular procedures, as well as to provide protection from the occupational hazards that are associated with interventional practice. Methods: Patients with coronary artery disease and clinical indications for percutaneous intervention were enrolled. The coronary intervention was performed with the CorPath 200 robotic system, which consists of a remote interventional cockpit and a bedside disposable cassette that enables the operator to advance, retract, and rotate guidewires and catheters. The primary endpoints were clinical procedural success, defined as <30% residual stenosis at the completion of the robotic-assisted procedure without major adverse cardiovascular events within 30 days, and device technical success, defined as the successful manipulation of the intracoronary devices using the robotic system only. Results: A total of 164 patients were enrolled at 9 sites. Percutaneous coronary intervention was completed successfully without conversion to manual operation, and device technical success was achieved in 162 of 164 patients (98.8%). There were no device-related complications. Clinical procedural success was achieved in 160 of 164 patients (97.6%), whereas 4 (2.4%) had periprocedural non-Q-wave myocardial infarctions. No deaths, strokes, Q-wave myocardial infarctions, or revascularization occurred in the 30 days after the procedures. Radiation exposure for the primary operator was 95.2% lower than the levels found at the traditional table position. Conclusions: This pivotal multicenter study with a robotic-enhanced coronary intervention system demonstrated the safety and feasibility of the system. The robotic remote-control procedure met the expected technical and clinical performance, with significantly lower radiation exposure to the operator. (Evaluation of the Safety and Effectiveness of the CorPath 200 System in Percutaneous Coronary Interventions [PCI] [PRECISE]; NCT01275092)
AB - Objectives: The aim of this study was to evaluate the safety as well as the clinical and technical effectiveness of robotic-assisted percutaneous coronary intervention. Background: Robotic systems have been suggested to enhance the performance of cardiovascular procedures, as well as to provide protection from the occupational hazards that are associated with interventional practice. Methods: Patients with coronary artery disease and clinical indications for percutaneous intervention were enrolled. The coronary intervention was performed with the CorPath 200 robotic system, which consists of a remote interventional cockpit and a bedside disposable cassette that enables the operator to advance, retract, and rotate guidewires and catheters. The primary endpoints were clinical procedural success, defined as <30% residual stenosis at the completion of the robotic-assisted procedure without major adverse cardiovascular events within 30 days, and device technical success, defined as the successful manipulation of the intracoronary devices using the robotic system only. Results: A total of 164 patients were enrolled at 9 sites. Percutaneous coronary intervention was completed successfully without conversion to manual operation, and device technical success was achieved in 162 of 164 patients (98.8%). There were no device-related complications. Clinical procedural success was achieved in 160 of 164 patients (97.6%), whereas 4 (2.4%) had periprocedural non-Q-wave myocardial infarctions. No deaths, strokes, Q-wave myocardial infarctions, or revascularization occurred in the 30 days after the procedures. Radiation exposure for the primary operator was 95.2% lower than the levels found at the traditional table position. Conclusions: This pivotal multicenter study with a robotic-enhanced coronary intervention system demonstrated the safety and feasibility of the system. The robotic remote-control procedure met the expected technical and clinical performance, with significantly lower radiation exposure to the operator. (Evaluation of the Safety and Effectiveness of the CorPath 200 System in Percutaneous Coronary Interventions [PCI] [PRECISE]; NCT01275092)
KW - angioplasty
KW - robotic-enhanced PCI
KW - stent
UR - http://www.scopus.com/inward/record.url?scp=84875986249&partnerID=8YFLogxK
U2 - 10.1016/j.jacc.2012.12.045
DO - 10.1016/j.jacc.2012.12.045
M3 - Article
C2 - 23500318
AN - SCOPUS:84875986249
SN - 0735-1097
VL - 61
SP - 1596
EP - 1600
JO - Journal of the American College of Cardiology
JF - Journal of the American College of Cardiology
IS - 15
ER -