Sapien 3 Transcatheter Aortic Valve Implantation with Moderate or Without Predilation

Yigal Abramowitz, Hasan Jilaihawi, Tarun Chakravarty, Yoshio Maeno, Hiroyuki Kawamori, Yoshio Kazuno, Geeteshwar Mangat, Tanya Rami, Zev Allison, David Anderson, Larry Chan, Wen Cheng, Raj R. Makkar

Research output: Contribution to journalArticlepeer-review

14 Scopus citations

Abstract

OBJECTIVES. Aortic valve preparation with balloon aortic valvuloplasty (BAV) has been previously considered mandatory during transcatheter aortic valve implantation (TAVI) procedures. BAV-inherent risks including stroke, conduction abnormalities, and reduced device profile size established the rationale for safe valve deployment without the need for aggressive valve preparation. We investigate the feasibility and safety of performing Sapien 3 (S3; Edwards Lifesciences) balloon-expandable TAVI with moderate or without predilation (PD). METHODS: We examined consecutive patients with severe aortic stenosis who underwent S3-TAVI at our institution. Overall, 119 patients underwent TAVI without PD and 126 with moderate PD (mean valvuloplasty balloon diameter, 15.3 ± 2.1 mm). TAVI endpoints and adverse events were considered according to the Valve Academic Research Consortium (VARC)-2 definitions. RESULTS: Device success for the entire cohort was 98.8%. PD rates were similar between groups. Total fluoroscopy time and amount of contrast used were lower in the no PD group (13 min vs 16.2 min [P<.001] and 71.3 mL vs 81 mL [P≤.03], respectively). All-cause mortality up to 30 days was 0% (0/119) in the no PD group vs 1.6% (2/126) in the moderate PD group (P≤.49). VARC-2 defined complication rates at 30 days including cerebrovascular accident were similar between groups. Overall, there was no significant difference in survival rate between both groups (hazard ratio, 3.6; 95% confidence interval, 0.80-16.2; P≤.09). CONCLUSIONS: Balloon-expandable TAVI using the S3 device with moderate or without balloon PD is feasible and safe. Omission of PD in appropriate cases was associated with reduced fluoroscopy time and total contrast used without affecting procedural success.

Original languageEnglish
Pages (from-to)421-426
Number of pages6
JournalJournal of Invasive Cardiology
Volume28
Issue number10
StatePublished - 1 Oct 2016
Externally publishedYes

Keywords

  • aortic stenosis
  • balloon aortic valvuloplasty
  • transcatheter aortic valve replacement

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'Sapien 3 Transcatheter Aortic Valve Implantation with Moderate or Without Predilation'. Together they form a unique fingerprint.

Cite this