TY - JOUR
T1 - Serum Angiotensin-Converting Enzyme Has a High Negative Predictive Value in the Investigation for Systemic Sarcoidosis
AU - Niederer, Rachael L.
AU - Al-Janabi, Ahmed
AU - Lightman, Sue L.
AU - Tomkins-Netzer, Oren
N1 - Publisher Copyright:
© 2018 Elsevier Inc.
PY - 2018/10/1
Y1 - 2018/10/1
N2 - Purpose: To examine whether measurement of serum angiotensin-converting enzyme (ACE) is useful in diagnosing sarcoidosis in undifferentiated uveitis. Design: Evaluation of a diagnostic test. Methods: Data collection was performed from 1035 consecutive subjects presenting with uveitis to Moorfields Eye Hospital undergoing measurement of serum ACE as part of baseline investigations for underlying systemic disease. The main outcome measures were sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of elevated serum ACE. Results: Mean age of the sample was 41.7 years and 56.1% of subjects were female. Sarcoidosis was the underlying cause for the uveitis in 110 subjects (10.6%) and was more common in adults, female subjects, black subjects, and subjects with intermediate uveitis or panuveitis. ACE was elevated in 196 subjects (18.9%) and elevated levels were observed in 85 subjects eventually diagnosed with underlying sarcoidosis (true positive 77.3%) and in 111 subjects with an alternate diagnosis (false positive 12.0%). In adult subjects, sensitivity of serum ACE was 78.1%, specificity 90.0%, and PPV 43.6%, but the NPV was 97.0%. The test performed well, with area under curve (AUC) 0.897 (95% confidence interval [CI] 0.854–0.941). Serum ACE performed less well in distinguishing sarcoid uveitis in pediatric subjects, with sensitivity 60.0%, specificity 78.5%, and PPV 10.0%, but again NPV was high at 96.9% and AUC was 0.828 (95% CI 0.571–1.000). Conclusions: Serum ACE had a very high negative predictive value for sarcoid uveitis, eliminating the need for further screening tests in subjects with normal serum ACE, unless clinical suspicion was high.
AB - Purpose: To examine whether measurement of serum angiotensin-converting enzyme (ACE) is useful in diagnosing sarcoidosis in undifferentiated uveitis. Design: Evaluation of a diagnostic test. Methods: Data collection was performed from 1035 consecutive subjects presenting with uveitis to Moorfields Eye Hospital undergoing measurement of serum ACE as part of baseline investigations for underlying systemic disease. The main outcome measures were sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of elevated serum ACE. Results: Mean age of the sample was 41.7 years and 56.1% of subjects were female. Sarcoidosis was the underlying cause for the uveitis in 110 subjects (10.6%) and was more common in adults, female subjects, black subjects, and subjects with intermediate uveitis or panuveitis. ACE was elevated in 196 subjects (18.9%) and elevated levels were observed in 85 subjects eventually diagnosed with underlying sarcoidosis (true positive 77.3%) and in 111 subjects with an alternate diagnosis (false positive 12.0%). In adult subjects, sensitivity of serum ACE was 78.1%, specificity 90.0%, and PPV 43.6%, but the NPV was 97.0%. The test performed well, with area under curve (AUC) 0.897 (95% confidence interval [CI] 0.854–0.941). Serum ACE performed less well in distinguishing sarcoid uveitis in pediatric subjects, with sensitivity 60.0%, specificity 78.5%, and PPV 10.0%, but again NPV was high at 96.9% and AUC was 0.828 (95% CI 0.571–1.000). Conclusions: Serum ACE had a very high negative predictive value for sarcoid uveitis, eliminating the need for further screening tests in subjects with normal serum ACE, unless clinical suspicion was high.
UR - https://www.scopus.com/pages/publications/85051568919
U2 - 10.1016/j.ajo.2018.07.010
DO - 10.1016/j.ajo.2018.07.010
M3 - Article
C2 - 30053466
AN - SCOPUS:85051568919
SN - 0002-9394
VL - 194
SP - 82
EP - 87
JO - American Journal of Ophthalmology
JF - American Journal of Ophthalmology
ER -