T1 - Surgical Telementoring Without Encumbrance
T2 - A Comparative Study of See-through Augmented Reality-based Approaches
AU - Rojas-Muñoz, Edgar
AU - Cabrera, Maria Eugenia
AU - Andersen, Daniel
AU - Popescu, Voicu
AU - Marley, Sherri
AU - Mullis, Brian
AU - Zarzaur, Ben
AU - Wachs, Juan
N1 - Publisher Copyright:
© 2019 Wolters Kluwer Health, Inc. All rights reserved.
PY - 2019/8/1
Y1 - 2019/8/1
N2 - Objective:This study investigates the benefits of a surgical telementoring system based on an augmented reality head-mounted display (ARHMD) that overlays surgical instructions directly onto the surgeon's view of the operating field, without workspace obstruction.Summary Background Data:In conventional telestrator-based telementoring, the surgeon views annotations of the surgical field by shifting focus to a nearby monitor, which substantially increases cognitive load. As an alternative, tablets have been used between the surgeon and the patient to display instructions; however, tablets impose additional obstructions of surgeon's motions.Methods:Twenty medical students performed anatomical marking (Task1) and abdominal incision (Task2) on a patient simulator, in 1 of 2 telementoring conditions: ARHMD and telestrator. The dependent variables were placement error, number of focus shifts, and completion time. Furthermore, workspace efficiency was quantified as the number and duration of potential surgeon-tablet collisions avoided by the ARHMD.Results:The ARHMD condition yielded smaller placement errors (Task1: 45%, P < 0.001; Task2: 14%, P = 0.01), fewer focus shifts (Task1: 93%, P < 0.001; Task2: 88%, P = 0.0039), and longer completion times (Task1: 31%, P < 0.001; Task2: 24%, P = 0.013). Furthermore, the ARHMD avoided potential tablet collisions (4.8 for 3.2 seconds in Task1; 3.8 for 1.3 seconds in Task2).Conclusion:The ARHMD system promises to improve accuracy and to eliminate focus shifts in surgical telementoring. Because ARHMD participants were able to refine their execution of instructions, task completion time increased. Unlike a tablet system, the ARHMD does not require modifying natural motions to avoid collisions.
AB - Objective:This study investigates the benefits of a surgical telementoring system based on an augmented reality head-mounted display (ARHMD) that overlays surgical instructions directly onto the surgeon's view of the operating field, without workspace obstruction.Summary Background Data:In conventional telestrator-based telementoring, the surgeon views annotations of the surgical field by shifting focus to a nearby monitor, which substantially increases cognitive load. As an alternative, tablets have been used between the surgeon and the patient to display instructions; however, tablets impose additional obstructions of surgeon's motions.Methods:Twenty medical students performed anatomical marking (Task1) and abdominal incision (Task2) on a patient simulator, in 1 of 2 telementoring conditions: ARHMD and telestrator. The dependent variables were placement error, number of focus shifts, and completion time. Furthermore, workspace efficiency was quantified as the number and duration of potential surgeon-tablet collisions avoided by the ARHMD.Results:The ARHMD condition yielded smaller placement errors (Task1: 45%, P < 0.001; Task2: 14%, P = 0.01), fewer focus shifts (Task1: 93%, P < 0.001; Task2: 88%, P = 0.0039), and longer completion times (Task1: 31%, P < 0.001; Task2: 24%, P = 0.013). Furthermore, the ARHMD avoided potential tablet collisions (4.8 for 3.2 seconds in Task1; 3.8 for 1.3 seconds in Task2).Conclusion:The ARHMD system promises to improve accuracy and to eliminate focus shifts in surgical telementoring. Because ARHMD participants were able to refine their execution of instructions, task completion time increased. Unlike a tablet system, the ARHMD does not require modifying natural motions to avoid collisions.
KW - augmented reality
KW - surgical telementoring
KW - telemedicine
KW - teleproctoring
UR - http://www.scopus.com/inward/record.url?scp=85069815514&partnerID=8YFLogxK
U2 - 10.1097/SLA.0000000000002764
DO - 10.1097/SLA.0000000000002764
M3 - Article
C2 - 29672404
AN - SCOPUS:85069815514
SN - 0003-4932
VL - 270
SP - 384
EP - 389
JO - Annals of Surgery
JF - Annals of Surgery
IS - 2
ER -