Abstract
Purpose: To describe a simple and novel technique of obtaining an extraocular muscle (EOM) biopsy. Methods: Our sutureless method involves obtaining a full-thickness 3-mm EOM specimen using a disposable punch biopsy. results: The procedure was performed successfully, with no worsening of eye movement, muscle weakness, or cosmetic defects postoperatively. The acquired full-thickness specimen was sufficient for analysis. conclusions: This technique to obtain an EOM biopsy allows a straightforward sutureless method, providing an adequate sample for tissue scrutiny.
Original language | English |
---|---|
Pages (from-to) | 614-616 |
Number of pages | 3 |
Journal | European Journal of Ophthalmology |
Volume | 27 |
Issue number | 5 |
DOIs | |
State | Published - 1 Sep 2017 |
Keywords
- Biopsy
- Extraocular muscle
- Technique