Abstract
The paper derives closed form expressions for transient and steady-state operation of a DC-DC converter with single switched capacitor. To this end, the result of each switching is considered as a point in the iterative process, and the function between the points is reconstructed. As opposed to the commonly accepted approach, when each of the topologies is approximated by a first order circuit, the proposed analysis is carried out for second order circuits. This allows obtaining the waveform of output voltage ripple and paves the way to more accurate calculation of equivalent resistance. The obtained analytical expressions were verified by simulations and an excellent agreement between the results was found.
Original language | English |
---|---|
Pages (from-to) | 342-350 |
Number of pages | 9 |
Journal | International Journal of Power Electronics and Drive Systems |
Volume | 10 |
Issue number | 1 |
DOIs | |
State | Published - 1 Mar 2019 |
Keywords
- Charge pump
- Discrete-time systems
- Equivalent resistance
- Switched capacitor converter
ASJC Scopus subject areas
- Energy Engineering and Power Technology
- Electrical and Electronic Engineering