Z - Accelerator and Dot Sensor (D - Dot Mode) System Electro Magnetic Pulse (EMP) Stability Analysis under Parameter Variation

Ofer Aluf

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

Abstract

A Z - accelerator Dot sensor (D - dot mode) is targeted to measure fast rise time voltage signals which are transmitted along a coaxial cable. The surrounding environment of a Dot sensor is gamma rays colliding with air molecules (high - altitude electromagnetic pulse (HEMP)) and plasma expansion (magneto hydro dynamic electromagnetic pulse (MHD-EMP)) influence the measurements and need to be measured. The Dot sensor purpose is to supply read of signal which is caused by pulse propagating to the inner conductor of the coaxial D - dot probe. The delay parameters τ1, τ2 characterise the HEMP and MHD-EMP interaction (parasitic effects which are second components of HEMP and MHD-EMP) with the Dot sensor. The investigation of electromagnetic pulses and Dot sensor system is based on nonlinear dynamic theory which describes changes in system variables over time, which can be chaotic, unpredictable, or counterintuitive. The target is to optimise Dot probe sensor parameters in the accelerator environment and understand the HEMP and MHD-EMP disturbances.

Original languageEnglish
Title of host publication2024 IEEE International Conference on Microwaves, Communications, Antennas, Biomedical Engineering and Electronic Systems, COMCAS 2024
PublisherInstitute of Electrical and Electronics Engineers
ISBN (Electronic)9798350348187
DOIs
StatePublished - 1 Jan 2024
Event2024 IEEE International Conference on Microwaves, Communications, Antennas, Biomedical Engineering and Electronic Systems, COMCAS 2024 - Tel Aviv, Israel
Duration: 9 Jul 202411 Jul 2024

Publication series

Name2024 IEEE International Conference on Microwaves, Communications, Antennas, Biomedical Engineering and Electronic Systems, COMCAS 2024

Conference

Conference2024 IEEE International Conference on Microwaves, Communications, Antennas, Biomedical Engineering and Electronic Systems, COMCAS 2024
Country/TerritoryIsrael
CityTel Aviv
Period9/07/2411/07/24

Keywords

  • Bifurcation
  • D - dot mode
  • Delay Differential Equation (DDE)
  • Dot sensor
  • Eigenstates
  • Eigenvalue
  • Fixed point
  • HEMP
  • MHD-EMP
  • Orbit
  • Stability
  • Z - accelerator

ASJC Scopus subject areas

  • Computer Networks and Communications
  • Biomedical Engineering
  • Electrical and Electronic Engineering
  • Instrumentation
  • Radiation